XM31-918-HP
Alarms
Alarms
Battery
Log In...
English
Español
Français
Português
Deutsch
Overview
Hardware
Power Supply
Batteries
Environmental I/O
Components
Network
DOCSIS
RF Attenuation
Ethernet
Advanced
Interfaces
Network Services
Diagnostics
Management
System Data
SNMP
Alarms
History
Power Supply Events
Power Supply Configuration
Battery Events
Standby Events
Modem Log
Network System Log
Network Event Log
Firewall Log
Alarm Log
Tools
Spectrum
Microreflections
d
Alarm Summary
0 major; 0 minor; 1 nominal; 38 disabled
s,hh,h,l,ll,d,c
Power Supply 1 - Limit Properties
State
Major High
Minor High
Minor Low
Major Low
Dead Band
Current Value
Output Voltage
Nominal
0.00
0.00
0.00
0.00
0.00
87.38
V
Input Voltage
Nominal
0.00
0.00
0.00
0.00
0.00
125.58
V
Battery String Voltage
Nominal
0.00
0.00
0.00
0.00
0.00
42.13
V
Output Power
Nominal
0
0
0
0
0
408
W
Output Frequency
Nominal
0.00
0.00
0.00
0.00
0.00
60.04
Hz
Input Current
Nominal
0.00
0.00
0.00
0.00
0.00
5.73
A
Input Power
Nominal
0
0
0
0
0
540
W
String A Charge Current
Nominal
0.00
0.00
0.00
0.00
0.00
0.00
A
String A Discharge Current
Nominal
0.00
0.00
0.00
0.00
0.00
0.00
A
String A Float Current
Nominal
0.00
0.00
0.00
0.00
0.00
0.05
A
Battery A1 Voltage
Nominal
12.40
12.30
11.90
11.85
0.01
14.13
V
Battery A2 Voltage
Nominal
12.40
12.30
11.90
11.85
0.01
14.09
V
Battery A3 Voltage
Nominal
12.40
12.30
11.90
11.85
0.01
14.04
V
Output 1 Current
Nominal
0.00
0.00
0.00
0.00
0.00
5.38
A
Sensor 1 Temperature
Nominal
0
0
0
0
0
11
°C
s,hh,h,l,ll,d,c
System - Limit Properties
State
Major High
Minor High
Minor Low
Major Low
Dead Band
Current Value
Downstream Power
Nominal
15.0
10.0
-10.0
-15.0
1.5
1.2
dBmV
Upstream Power
Nominal
55.0
50.0
0.0
0.0
1.5
49.3
dBmV
Generator Powering
Nominal
0
0
0
0
0
0
min
Inverter Runtime
Nominal
0
0
0
0
0
587
min
Time in Standby
Nominal
0
0
0
0
0
0
sec
Time in Last Standby Event
Nominal
0
0
0
0
0
60
sec
Internal Temperature
Nominal
0
0
0
0
0
41
°C
v,s,e,c
Power Supply 1 - Discrete Properties
Setting
State
Enable
Current Value
Inverter Status
Off
Nominal
Disable
Off
Line failure
Nominal
Disable
Test cycle
Nominal
Disable
Test started
Nominal
Disable
Test failed
Nominal
Disable
Major Alarm
OK
Nominal
Disable
Alarm
Alarm
Nominal
Disable
Minor Alarm
OK
Nominal
Disable
OK
Alarm
Nominal
Disable
Tamper
Door closed
Nominal
Disable
Door closed
Door open
Nominal
Disable
Input Voltage Presence
Voltage lost
Nominal
Disable
OK
OK
Nominal
Disable
v,s,e,c
System - Discrete Properties
Setting
State
Enable
Current Value
HTTP Login Edits Level
No edits
Nominal
Disable
No edits
Some edits
Nominal
Disable
All edits
Nominal
Disable
Generator State
Not installed
Nominal
Disable
Not installed
Off
Nominal
Disable
Running
Nominal
Disable
Not detected
Nominal
Disable
Error
Nominal
Disable
I/O Pin 3 Status
Open
Nominal
Disable
Open
Closed
Nominal
Disable
I/O Pin 4 Status
Open
Nominal
Disable
Open
Closed
Nominal
Disable
I/O Pin 5 Status
Open
Nominal
Disable
Open
Closed
Nominal
Disable
I/O Pin 6 Status
Open
Nominal
Disable
Open
Closed
Nominal
Disable
I/O Pin 7 Status
Open
Nominal
Disable
Open
Closed
Nominal
Disable
I/O Pin 8 Status
Open
Nominal
Disable
Open
Closed
Nominal
Disable
DTR Monitor Status
DTR detection disabled
Nominal
Enable minor
DTR safe
DTR safe
Nominal
Disable
DTR detection running
Nominal
Disable
DTR required reboot approaching
Nominal
Enable minor
DTR reboot imminent
Nominal
Enable major
Battery Standby Time Remaining
Over three hours
Nominal
Disable
Not available
Two to three hours
Nominal
Disable
One to two hours
Nominal
Disable
Less than one hour
Nominal
Disable
Calculating
Nominal
Disable
Not available
Nominal
Disable
Craft Port
Not connected
Nominal
Disable
Not connected
Connected
Nominal
Disable
Transponder Control Mode
Remote access
Nominal
Disable
Remote access
Local access only
Nominal
Disable
Not communicating
Nominal
Disable
→ CSV
→ Excel
Copyright © 2017-2022 EnerSys. All Rights Reserved.
www.alpha.com
|
www.enersys.com
Close